OOHMAGE OMM7-320 New Energy High-Voltage MCCB
Engineered for high-energy AC distribution up to 1,140 V, the OOHMAGE OMM7-320 New Energy High-Voltage Circuit Breaker combines compact form, high breaking capacity, and “zero-arc” switching architecture. Its thermomagnetic trip with selectable instantaneous release (5 In / 10 In) and modular internal accessories make it a robust choice for renewables, heavy industry, mining, and traction auxiliaries—especially where heat, altitude, and tight panels challenge ordinary mccb designs.
Why it stands out
- High breaking capacity across high voltages: up to Icu/Ics 100/100 kA @ 380/415 V (H code); 65/65 kA @ 690 V, 50/50 kA @ 800 V, 30/30 kA @ 1,000 V, 20/20 kA @ 1,140 V—stable protection for large feeders where mccb 3 phase is the norm.
- No capacity derating at +50 °C: thermal design keeps the trip unit within calibration without upsizing.
- Zero-arc switching path: optimized arc-chute and blow-out geometry reduce arc exposure at opening—safer for dense busbar chambers.
- Modular accessories: plug-in internal modules (shunt/UVT/aux) and external handles simplify setting mccb, interlocks, and maintenance.
- Insulation & surge margin: Ui 1,200 V, Uimp 12 kV, PF withstand 3.5 kV/1 min—built for harsh transients.
- Compact envelope: short arc distance (50–100 mm frame-dependent) enables smaller enclosures and lower heat-load.
Ratings by frame (3-pole)
- OMM7-320 (16–320 A)
- Voltages: AC 380/415, 690, 800, 1,000, 1,140 V
- Breaking capacity (Icu/Ics, kA):
- H: 100/100 (415 V); 65/65 (690 V); 50/50 (800 V); 30/30 (1,000 V); 20/20 (1,140 V)
- M: — / 60/60 (690 V); 50/50 (800 V); 20/20 (1,000 V); 12/12 (1,140 V)
- Life: Mech 15,000; Elec 5,000 / 3,000 / 1,000 (by voltage)
- Size (W×L×H, mm): 120×200×103; Arc distance 50 mm
- OMM7-630 (225–630 A)
- Icu/Ics up to 65/65 kA @ 690 V, 50/50 kA @ 800 V, 30/30 kA @ 1,000 V, 20/20 kA @ 1,140 V
- Life: Mech 15,000; Elec 5,000 / 3,000 / 1,000
- Size: 158×325×177 mm; Arc distance 100 mm
- OMM7-1250 (800–1250 A)
- Icu/Ics (H): 50/50 kA @ 800 V, 30/30 kA @ 1,000 V, 20/20 kA @ 1,140 V
- Life: Mech 15,000; Elec 5,000 / 3,000 / 1,000
- Size: 210×340×244 mm; Arc distance 100 mm
Application guidance (fungsi mccb)
- Utility & renewable switchboards: 690–1,000 V collectors, string-inverter mains, battery energy storage feeders.
- Industrial drives & mining: 690–800 V motors, hoists, crushers; high Icu with compact footprint.
- Transport & marine auxiliaries: high-voltage auxiliaries where mccb 400a and above are common, plus elevated ambient operation.
Protection & settings
- Trip unit: thermomagnetic, instantaneous 5 In / 10 In selection per frame.
- Coordination: high Ics/Icu parity simplifies Type-2 coordination and downstream selectivity.
- Accessories: shunt trip, undervoltage release, auxiliary/alarm contacts, motor operator, rotary handle kits—streamlined for panel retrofits and compliant setting mccb procedures.
OOHMAGE value for buyers (harga mccb context)
Selecting by Icu/Ics at your operating voltage (not just ampere size) delivers the best cost-to-risk outcome. OMM7’s no-derate at +50 °C and modular options reduce oversizing, installation space, and lifecycle cost—key considerations for procurement teams comparing harga mccb across suppliers.
Technical Specifications
| New Energy Height Voltage Circuit Breaker OMM7- | 320 | 630 | 1250 | ||||||||
| Rated current | 16A~320A | 225A~630A | 800A~1250A | ||||||||
| Number of poles | 3P | ||||||||||
| Rated working voltage Ue AC 50-60Hz | AC380/415V、AC690V、AC800V、AC1000V、AC1140V | ||||||||||
| Rated insulation voltage Ui | 1200V | ||||||||||
| Rated impulse withstand voltage Uimp | 12kV | ||||||||||
| Power frequency withstand voltage (1min) | 3500V | ||||||||||
| Rated ultimate short-circuit breaking capacity lcu(kA) | Breaking capacity level | AC380/415V | AC690V | AC800V | AC1000V | AC1140V | |||||
| M | / | 60 | 50 | 20 | 12 | ||||||
| H | 100 | 65 | 50 | 30 | 20 | ||||||
| Rated service short-circuit breaking capacity Ics(kA) | M | 60 | 50 | 20 | 12 | ||||||
| H | 100 | 65 | 50 | 30 | 20 | ||||||
| Mechanical life | 15000 | 15000 | 15000 | ||||||||
| Electrical life | 5000 3000 1000 | 5000 3000 | 1000 | 5000 3000 1000 | |||||||
| Arc distance | 50 | 100 | 100 | ||||||||
| Basic dimension W×L×H | 120*200*103 | 158*325*177 | 210*340*244 | ||||||||
| Instantaneous release | 5ln or 10In | 5In or 10In | 5ln or 10In | ||||||||
| Reference ambient temperature | 40℃ | 40℃ | 40℃ | ||||||||
Why Choose OOHMAGE
Specify OOHMAGE OMM7-320 High-Voltage MCCB for compact, zero-arc, high-Icu protection up to 1,140 V.
Ask for a project quote and coordination sheet (single-line + accessory BOM) to match frame, breaking capacity, and ambient conditions to your switchboard standard.
Request Quote
Tell us your specifications, quantity, or application scenario and we will reply with a tailored quote.