OOHMAGE OMM6LE Residual Current Operated Circuit Breaker — Remote-ready MCCB with Leakage Protection
The OOHMAGE OMM6LE is a residual-current operated mccb engineered for AC 400 V three-phase systems (4P, 3P+N). It integrates remote control, adjustable leakage protection and cost-control metering to simplify protection design and O&M. With up to Icu/Ics 65/50 kA @ 400 V, the breaker suits feeders and incomers in commercial buildings, industrial plants and energy-aware facilities.
Why choose OMM6LE
- Residual-current leakage protection: Electronic trip module with selectable IΔn stages safeguards personnel and equipment and helps reduce arc-flash risk in mccb distribution.
- Remote control (MD ready): Optional motor operator enables open/close, reset and status feedback for SCADA/BMS; supports external rotary handle for safe local operation.
- Cost control function: Built-in measurement channels support kWh/cost allocation and alarms, cutting add-on meters and wiring.
- Chinese–English shift: Dual-language HMI streamlines commissioning and maintenance across teams.
- Robust short-circuit performance: Up to 65 kA Icu / 50 kA Ics at 400 V allows selective coordination with upstream/downstream mccb 3 phase devices.
- OOHMAGE build: Compact body, low temperature rise and consistent trip curves across the full specification range.
Technical Parameters
| Residual Current Operated Circuit Breaker OMM6LE- | 250 | 400/630 | 800 | 1250 | ||||||||
| Number of poles | 4P(3P+N) | |||||||||||
| Rated current(A) | 50A~125A 100A~250A | 160A~400A 252A~630A | 252A~630A 320A~800A | 400A~1000A 500A~1250A | ||||||||
| Rated voltage (V) | AC400V | |||||||||||
| Rated insulation voltage(V) | AC1000V | |||||||||||
| Short circuit breaking capacity (kA)Icu/lcs | AC400V | 50/35 | 65/50 | |||||||||
| Number of operation cycles | Power-on | 1000 | 1000 | 500 | 500 | |||||||
| Power-off | 7000 | 4000 | 2500 | 2500 | ||||||||
Outline dimension(mm)![]() b-a-ca | 4P(3P+N) | 240*142*138 | 336*198*181 | 275.5*280*169 | 275.5*280*169 | |||||||
| Electrical motor device(MD) | ● | Extemal transmission operating handle | ● | Automatic release device | Electronic type | |||||||
Engineering notes
- Coordination & selectivity: Use upstream/downstream curve staging (Icu/Ics 65/50 kA tier) to maintain service continuity in mccb 3 phase risers; apply ground-fault/residual settings per feeder leakage profile.
- Remote operation safety: Combine MD with door-mounted handle; adopt interlocks to block local closing during remote sequences.
- Thermal performance: Low temperature rise supports denser panels; respect cable cross-section and ventilation to keep conductor ΔT within design limits.
- Commissioning workflow: CN/EN UI reduces setup friction; document setting mccb parameters (IΔn, delays, Inst) in the single-line schedule.
Why OOHMAGE
Deploy OOHMAGE OMM6LE where you need residual-current protection, remote control and verifiable cost allocation in one mccb. Ask for the coordination file and MD wiring diagram to finalize settings and get a project-bundle quote.
Request Quote
Tell us your specifications, quantity, or application scenario and we will reply with a tailored quote.