OOHMAGE OMM6LE IoT Reclosing Circuit Breaker — Smart MCCB with Remote Reclose & Early-Warning
The OOHMAGE OMM6LE IoT Reclosing Circuit Breaker is a 4-pole (3P+N) smart mccb for AC 400 V systems, engineered for remote control, automatic reclosing, power metering statistics, and rapid fault location. Its electronic release supports coordinated protection on feeders where uptime and granular monitoring matter. Built on a compact platform with robust short-circuit performance (up to Icu/Ics 65/50 kA @ 400 V), it’s well suited to critical distribution panels, commercial buildings, industrial plants, and energy-managed facilities.
Key Advantages
Remote control & auto-reclose: Open/close from SCADA/BMS and enable adaptive reclosing after transient faults to reduce downtime.
Power metering statistics: Onboard measurement for kWh, demand snapshots, and event logs improves load profiling and cost allocation.
Early-warning protection: Threshold alarms (overload trend, temperature rise surrogate via current profile, leakage pre-alarms when paired with upstream RCD) help prevent nuisance trips.
Fast fault location: Time-stamped trip cause and phase identification shorten MTTR in multi-feeder boards.
OOHMAGE build: Low temperature rise, compact envelope, and consistent trip characteristics across the whole current range.
Technical Parameters
| loT Reclosing Circuit Breaker OMM6LE- | 160/GZ | 250/GZ | 400/630/GZ | 800/GZ | 1250/GZ | |||||||
| Number of poles | 4P(3P+N) | |||||||||||
| Rated current(A) | 40A~100A 63A~160A | 50A~125A 100A~250A | 160A~400A 252A~630A | 252A~630A 320A~800A | 400A~1000A 500A~1250A | |||||||
| Rated voltage(V) | AC400V | |||||||||||
| Rated insulation voltage(V) | AC1000V | |||||||||||
| Short circuit breaking capacity(kA) lcu/lcs | AC400V | 50/35 | 50/35 | 65/42 | 65/50 | 65/50 | ||||||
| Number of operation cycles | Power-on | 1500 | 1000 | 1000 | 500 | 500 | ||||||
| Power-off | 8500 | 7000 | 4000 | 2500 | 2500 | |||||||
| Outline dimension(mm) b-a-ca ![]() | 4P(3P+N) | 180*120*109 | 240*142*100 | 336*198*157 | 275.5*280*169 | 275.5*280*169 | ||||||
| Electric operating device | ● | External transmission operating handle | ● | Automatic release device | Electronic | |||||||
Engineering Notes
Coordination: Use mccb 3 phase selectivity with upstream incomers; set reclose logic only for transient faults (e.g., instantaneous/short delay trips) and lockout on persistent faults.
Thermal margins: Low ΔT frame allows denser busbar spacing; for higher frames, check enclosure ventilation and conductor sizing for continuous load plus harmonics.
Telemetry: Map metering, breaker state, trip cause, and reclose counters to BMS tags for analytics-driven maintenance and energy KPIs.
Commissioning: Document setting mccb parameters (LSI thresholds, reclose attempts, dead time) and store with panel as-built for audits.
Why OOHMAGE
Request Quote
Tell us your specifications, quantity, or application scenario and we will reply with a tailored quote.