OMM6LE Residual Current Operated Circuit Breaker

  • Remote control
  • Residual current leakage protection
  • Cost control function
  • Chinese-English shift

Download PDF
Share to:

OOHMAGE OMM6LE Residual Current Operated Circuit Breaker — Remote-ready MCCB with Leakage Protection

The OOHMAGE OMM6LE is a residual-current operated mccb engineered for AC 400 V three-phase systems (4P, 3P+N). It integrates remote control, adjustable leakage protection and cost-control metering to simplify protection design and O&M. With up to Icu/Ics 65/50 kA @ 400 V, the breaker suits feeders and incomers in commercial buildings, industrial plants and energy-aware facilities.

Why choose OMM6LE

  • Residual-current leakage protection: Electronic trip module with selectable IΔn stages safeguards personnel and equipment and helps reduce arc-flash risk in mccb distribution.
  • Remote control (MD ready): Optional motor operator enables open/close, reset and status feedback for SCADA/BMS; supports external rotary handle for safe local operation.
  • Cost control function: Built-in measurement channels support kWh/cost allocation and alarms, cutting add-on meters and wiring.
  • Chinese–English shift: Dual-language HMI streamlines commissioning and maintenance across teams.
  • Robust short-circuit performance: Up to 65 kA Icu / 50 kA Ics at 400 V allows selective coordination with upstream/downstream mccb 3 phase devices.
  • OOHMAGE build: Compact body, low temperature rise and consistent trip curves across the full specification range.

Technical Parameters

Residual Current Operated Circuit Breaker OMM6LE-250400/6308001250
Number of poles  4P(3P+N)
Rated current(A)50A~125A
100A~250A
160A~400A
252A~630A
252A~630A
320A~800A
400A~1000A
500A~1250A
Rated voltage (V)AC400V
Rated insulation voltage(V)AC1000V
Short circuit breaking capacity (kA)Icu/lcsAC400V50/3565/50
Number of operation cyclesPower-on10001000500500
Power-off7000400025002500
Outline dimension(mm)
cf416228-0b01-45da-81ac-9f15587cb7d0
b-a-ca
4P(3P+N)240*142*138336*198*181275.5*280*169275.5*280*169
Electrical motor device(MD)●Extemal transmission operating handle●Automatic release deviceElectronic type

Engineering notes

  • Coordination & selectivity: Use upstream/downstream curve staging (Icu/Ics 65/50 kA tier) to maintain service continuity in mccb 3 phase risers; apply ground-fault/residual settings per feeder leakage profile.
  • Remote operation safety: Combine MD with door-mounted handle; adopt interlocks to block local closing during remote sequences.
  • Thermal performance: Low temperature rise supports denser panels; respect cable cross-section and ventilation to keep conductor ΔT within design limits.
  • Commissioning workflow: CN/EN UI reduces setup friction; document setting mccb parameters (IΔn, delays, Inst) in the single-line schedule.

Why OOHMAGE

Deploy OOHMAGE OMM6LE where you need residual-current protection, remote control and verifiable cost allocation in one mccb. Ask for the coordination file and MD wiring diagram to finalize settings and get a project-bundle quote.

Request Quote

Tell us your specifications, quantity, or application scenario and we will reply with a tailored quote.

+86-18757092555 Phone info@oohmage.com E-mail Chat on WhatsApp WhatsApp