OOHMAGE OMM6EY Intelligent Measurement “Four-Remote” MCCB
The OOHMAGE OMM6EY Intelligent Measurement Four Remote Circuit Breaker is a smart MCCB for AC 400 V systems that blends metering, telecontrol and high breaking capacity in a compact frame. Designed for modern panels that need fast diagnostics and SCADA readiness, it delivers Icu/Ics up to 70 kA, selective category B, and ≤1 s remote actuation—ideal for plants, data centers, OEM switchboards, and distributed energy projects.
Why spec OMM6EY
- Four Telecontrol Functions (4-Remote): remote measurement, indication, control, and parameter adjustment for fast fault response and SCADA integration.
- Integrated metering: on-board voltage/current/energy measurement reduces extra meters and wiring; supports load profiling and energy audits.
- Dedicated carrier module: reliable comms for long cable runs and noisy electrical environments.
- High breaking capacity: lcu/lcs = 65–70 kA at AC400 V (frame dependent) with ICW up to 10 kA/1 s for selective coordination.
- Stable thermals: small volume with low temperature rise supports dense boards and extended duty.
- Maintenance strategy: maintenance-free option available; with-maintenance life up to 10,000 mechanical cycles.
Model range & ratings (summary)
- Frames / Poles: 250P/LCN, 400P/LCN, 630P/LCN • 3P
- Rated frame current (Inm): 250 / 400 / 630 A
- Adjustable In (range): 125 A (50–125 A), 250 A (100–250 A), 400 A (160–400 A), 630 A (252–630 A)
- System voltage: Ue AC400 V, Ui 1000 V, Uimp 8 kV
- Breaking performance (AC400 V): Icu/Ics 65 kA (250), 70 kA (400/630); Selective category B
- Short-time withstand (ICW): 5 kA/1 s (250), 8 kA/1 s (400), 10 kA/1 s (630)
- Response time: ≤ 1 s (remote operation)
- Life: Electrical 1,000 ops; Mechanical up to 10,000 ops (with maintenance)
- Dimensions (L×W×H): 165×105×133 mm (250) • 257×140×162 mm (400/630)
Application notes
- Industrial feeders & MCCs: coordinate at AC400 V using Ics/Icu values; use ICW for busbar selectivity.
- Smart panels: leverage 4-Remote for load shedding, peak-demand control, and breaker health alarms.
- Digitized facilities: built-in metering supports ESG reporting and energy optimization without external meters.
Technical Specifications
| Intelligent Measurement Four Remote Circuit Breaker OMM6EY- | 250P/LCN | 400P/LCN | 630P/LCN | |||
| Rated frame curent Inm(A) | 250 | 400 | 630 | |||
| Rated curent In(A) | 125(50-125A) 250(100-250A) | 400(160-400A) | 630(252-630A) | |||
| Rated working voltageUe(V) | AC400V | |||||
| Rated insulation voltageUi(V) | 1000 | |||||
| Rated impulse withstand voltageUlimp(kV) | 8 | |||||
| Number of poles | 3P | 3P | 3P | |||
| Rated ultimate short-circuit breaking capacity lcu(kA) | AC400V | 65 | 70 | 70 | ||
| Rated service short-circuit breaking capacity lcs(kA) | AC400V | 65 | 70 | 70 | ||
| Selective category | B | B | B | |||
| ICW | 5kA/1s | 8kA/1s | 10kA/1s | |||
| Electrical life (times) | 1000 | 1000 | 1000 | |||
| Mechanical life | Maintenance free | 7000 | 4000 | 4000 | ||
| With maintenance | 10000 | 7000 | 7000 | |||
| Quick response time for operation | ≤1s | ≤1s | ≤1s | |||
| Outline dimension (Lmm*Wmm*Hmm) | 165*105*133 | 257*140*162 | 257*140*162 | |||
Why OOHMAGE
Upgrade your smart panel with the OOHMAGE OMM6EY intelligent MCCB—mccb control, metering, and 4-Remote in one device.
Request a specification & coordination sheet to map trip curves, mccb 3 phase selectivity, and communication options to your single-line—plus a fast harga mccb quotation for project bundles.
Request Quote
Tell us your specifications, quantity, or application scenario and we will reply with a tailored quote.