< img height="1" width="1" src="https://www.facebook.com/tr?id=1523171142290993&ev=PageView&noscript=1"/>
Low-Voltage Protection Portfolio

Low-Voltage Circuit Protection Solutions

Build a clearer product shortlist for distribution, panel building and project orders. OOHMAGE supplies MCB, MCCB, RCCB, RCBO and surge protective device ranges for low-voltage protection requirements, with the final product choice confirmed against the selected series and application.

Send the circuit role, system details, known ratings, quantity, destination market and document requirements. If the final model is not yet known, begin with the application and the protection function you need to discuss.

Start with your application

Send the details already available

  • Protection function or product family
  • System voltage and AC or DC use
  • Known current, poles or breaking-capacity requirements
  • Quantity, destination market and required documents

Final model selection is confirmed against the selected series and application.

Choose Protection by Application

A product name is only the beginning of selection. The device must match the protection function, its position in the electrical arrangement and the project information available at the time of inquiry.

RequirementProduct range to reviewConfirm before model discussion
Branch-circuit overcurrent protectionMCBCircuit application, system voltage, rated current, poles, AC or DC use, trip-curve requirement and quantity.
Feeder or distribution overcurrent protectionMCCBSystem voltage, rated current, poles, required breaking capacity, trip-unit requirement, application and quantity.
Residual-current protection without integral overcurrent protectionRCCBRequired residual-current function, electrical arrangement, ratings, poles and coordination with the selected overcurrent protection.
Residual-current and overcurrent protection in one deviceRCBOCircuit application, ratings, poles, residual-current requirement, destination market and quantity.
Protection against transient overvoltage within a coordinated arrangementSPDAC or DC system, installation point, SPD type or project requirement, system parameters and documentation needs.

This matrix identifies a product family, not a final model. Confirm the published parameters of the selected series and the requirements that apply to the installation and destination market.

Explore Circuit Protection Product Ranges

Compare the role and published model details of each range before discussing a final shortlist.

OOHMAGE OMC8 2-pole miniature circuit breaker (MCB)
MCB

Miniature Circuit Breakers

Review MCB series for branch circuits, distribution boards, control panels and other suitable low-voltage applications. Compare the published model details, then include the required current rating, pole configuration, system and quantity in your inquiry.

OOHMAGE OMM6 thermomagnetic molded case circuit breaker (MCCB)
MCCB

Molded Case Circuit Breakers

Review thermomagnetic, electronic, adjustable and DC-rated MCCB options according to the published parameters of each series. For a focused quotation discussion, include system voltage, rated current, poles, required breaking capacity, application and quantity.

OOHMAGE OML8X 3P+N residual current circuit breaker (RCCB)
RCCB

Residual Current Circuit Breakers

Review RCCB series when residual-current protection is required without integral overcurrent protection. The wider protection arrangement still needs to be considered, including the overcurrent device used with the selected RCCB where applicable.

OOHMAGE OMi8X residual current circuit breaker with overcurrent protection (RCBO)
RCBO

Residual Current Circuit Breakers with Overcurrent Protection

Review RCBO series when one device is required to provide residual-current and overcurrent protection for an individual circuit. Confirm the circuit application, known ratings, poles, quantity and destination market before final model selection.

OOHMAGE OMYCH25 Type 1+2 surge protective device (SPD)
SPD

Surge Protective Devices

Review SPD series as part of a wider protection arrangement for transient overvoltage. An SPD is not a circuit breaker; selection depends on the electrical system, installation point, required protection arrangement and the specific series under consideration.

Start with the Details That Matter

A useful inquiry can begin before every specification is finalized. Send the information already available:

  • required product type or protection function;
  • intended circuit, panel, equipment or project application;
  • system voltage and AC or DC use;
  • known current rating, poles, breaking-capacity requirement or other selection details;
  • estimated quantity and packaging requirements;
  • destination market;
  • required technical or certification documents.

If you are comparing several product families, list the intended role of each item. This helps separate the requirements for branch circuits, feeders, residual-current protection and surge protection before a model and quotation are discussed.

From Product Selection to Order Coordination

OOHMAGE supports overseas buyers through product-range discussion, model confirmation and order coordination. Depending on the confirmed series and order requirements, the discussion can include product matching, OEM or ODM packaging, technical and certification document support, outgoing inspection arrangements and export order details.

01

Requirements

Share the application, system details, known ratings, quantity and destination market.

02

Product Shortlist

Separate branch, feeder, residual-current and surge-protection roles before model discussion.

03

Model & Documents

Confirm the selected series, published parameters and required technical or certification documents.

04

Quotation

Align the confirmed product list with quantity, packaging and export order requirements.

Documentation is confirmed for the selected product series and order requirement. A general product-family page should not be treated as proof that every model carries the same certification, rating or test record.

Technical Guides for Product Selection

Use these guides to clarify the protection function before requesting a quotation.

Types of Circuit Breakers: MCB, MCCB, RCCB and RCBO

MCCB Selection Guide

What Are RCBOs?

Surge Protective Device Selection Guide

Distribution Box Product Range

Frequently Asked Questions

What information should I include in a circuit protection inquiry?

Include the application, product type or protection function, known system details and ratings, quantity, destination market and document requirements. If a final model is not known, share the circuit or panel requirement first.

Can several product ranges be discussed in one inquiry?

Yes. A product list can include MCB, MCCB, RCCB, RCBO, SPD and related low-voltage products. Identify the intended application and available requirements for each item so the ranges can be reviewed separately.

Can technical or certification documents be checked before an order?

Document requirements can be discussed before the order is confirmed. State the destination market, selected or proposed product series and the documents required. Availability and scope are confirmed against the relevant model or series.

Do I need to select the final model before contacting OOHMAGE?

No. Begin with the application, protection function and any known ratings. The available product range can then be narrowed without guessing at a model.

Discuss Your Product Requirements

Send your application, system details, known ratings, quantity and destination market. The next discussion can focus on a practical product shortlist and the information needed for quotation.

OOHMAGE-COMPANY

Get Quote Today

We will reply to your message as soon as possible

+86-18757092555 Phone info@oohmage.com E-mail Chat on WhatsApp WhatsApp