{"id":7144,"date":"2025-09-24T03:02:30","date_gmt":"2025-09-24T03:02:30","guid":{"rendered":"https:\/\/www.oohmage.com\/?post_type=product&#038;p=7144"},"modified":"2026-07-10T05:56:32","modified_gmt":"2026-07-10T05:56:32","slug":"omdh6-25-dc-t1t2-dc-spd","status":"publish","type":"product","link":"https:\/\/www.oohmage.com\/th\/dc-surge-protection-device\/omdh6-25-dc-t1t2-dc-spd\/","title":{"rendered":"OMDH6.25-DC T1+T2 DC SPD \u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u0e1b\u0e49\u0e2d\u0e07\u0e01\u0e31\u0e19\u0e44\u0e1f\u0e01\u0e23\u0e30\u0e0a\u0e32\u0e01\u0e01\u0e23\u0e30\u0e41\u0e2a\u0e15\u0e23\u0e07"},"content":{"rendered":"<h2 data-start=\"386\" data-end=\"611\"><strong data-start=\"389\" data-end=\"435\">OOHMAGE MDH6.25 DC Surge Protective Device<\/strong> \u2013 Advanced Surge Protection for Solar and Industrial DC Systems<\/h2>\n<p data-start=\"613\" data-end=\"691\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Protecting your DC electrical systems from lightning-induced surges and transient overvoltages is crucial. The OOHMAGE MDH6.25 DC Surge Protective Device (SPD) offers robust Type 1+2 surge protection, ensuring the safety and efficiency of photovoltaic (PV) systems, industrial DC circuits, and battery storage infrastructures.<\/span><\/p>\n<hr data-start=\"693\" data-end=\"696\" \/>\n<h3 data-start=\"698\" data-end=\"751\"><strong data-start=\"705\" data-end=\"751\">Engineered for Maximum DC Surge Protection<\/strong><\/h3>\n<p data-start=\"753\" data-end=\"831\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">This Type 1+2 DC surge protection device is designed to meet IEC\/EN 61643-11 and GB\/T 18802.31 standards. It effectively shields against high-energy lightning surges and reduces risks from low-voltage transients that can damage your systems over time.<\/span><\/p>\n<h4 data-start=\"833\" data-end=\"857\">\u2b50 <strong data-start=\"840\" data-end=\"857\">Key Features:<\/strong><\/h4>\n<ul data-start=\"859\" data-end=\"1755\">\n<li data-start=\"859\" data-end=\"977\">\n<p data-start=\"861\" data-end=\"977\"><strong data-start=\"861\" data-end=\"898\">Dual-Stage Protection (Type 1+2):<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Combines capabilities of both surge suppressor and surge protector for comprehensive defense.<\/span><\/p>\n<\/li>\n<li data-start=\"979\" data-end=\"1090\">\n<p data-start=\"981\" data-end=\"1090\"><strong data-start=\"981\" data-end=\"1011\">High Discharge Capability:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Handles 20kA nominal discharge current and up to 40kA maximum discharge current for reliable safety.<\/span><\/p>\n<\/li>\n<li data-start=\"1092\" data-end=\"1205\">\n<p data-start=\"1094\" data-end=\"1205\"><strong data-start=\"1094\" data-end=\"1126\">MOV-Based Surge Suppression:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Advanced Metal Oxide Varistor (MOV) technology ensures fast and efficient clamping.<\/span><\/p>\n<\/li>\n<li data-start=\"1207\" data-end=\"1313\">\n<p data-start=\"1209\" data-end=\"1313\"><strong data-start=\"1209\" data-end=\"1234\">Low Residual Voltage:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Limits stress on connected electronics, enhancing system longevity.<\/span><\/p>\n<\/li>\n<li data-start=\"1315\" data-end=\"1426\">\n<p data-start=\"1317\" data-end=\"1426\"><strong data-start=\"1317\" data-end=\"1347\">Thermal Cut-Off Mechanism:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Activates disconnection in high-heat fault conditions to prevent overheating.<\/span><\/p>\n<\/li>\n<li data-start=\"1428\" data-end=\"1532\">\n<p data-start=\"1430\" data-end=\"1532\"><strong data-start=\"1430\" data-end=\"1453\">LED Status Monitor:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Visual indicators (Green\/Red) for fault and operation status.<\/span><\/p>\n<\/li>\n<li data-start=\"1534\" data-end=\"1643\">\n<p data-start=\"1536\" data-end=\"1643\"><strong data-start=\"1536\" data-end=\"1564\">Remote Signaling Option:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Seamless integration into smart monitoring panels for real-time system status tracking.<\/span><\/p>\n<\/li>\n<li data-start=\"1645\" data-end=\"1755\">\n<p data-start=\"1647\" data-end=\"1755\"><strong data-start=\"1647\" data-end=\"1676\">Compact &amp; Durable Design:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">DIN rail mountable, constructed with flame-retardant thermoplastic (UL94-V0).<\/span><\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1757\" data-end=\"1760\" \/>\n<h2 data-start=\"1762\" data-end=\"1865\">\ud83c\udfe2 <strong data-start=\"1765\" data-end=\"1813\">Wide Applications of This DC Surge Protector<\/strong><\/h2>\n<p data-start=\"1867\" data-end=\"1884\">Ideal for use in:<\/p>\n<ul data-start=\"1886\" data-end=\"2216\">\n<li data-start=\"1886\" data-end=\"1993\">\n<p data-start=\"1888\" data-end=\"1993\"><strong data-start=\"1888\" data-end=\"1912\">Solar Energy Systems<\/strong> \u2013 <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Protects photovoltaic panels and inverters from surge damage.<\/span><\/p>\n<\/li>\n<li data-start=\"1995\" data-end=\"2104\">\n<p data-start=\"1997\" data-end=\"2104\"><strong data-start=\"1997\" data-end=\"2023\">Industrial DC Circuits<\/strong> \u2013 <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Ensures reliable surge protection in factories and production lines.<\/span><\/p>\n<\/li>\n<li data-start=\"2106\" data-end=\"2216\">\n<p data-start=\"2108\" data-end=\"2216\"><strong data-start=\"2108\" data-end=\"2135\">Battery Storage Systems<\/strong> \u2013 <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Safeguards energy storage units against voltage spikes.<\/span><\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"4342\" data-end=\"4445\">\ud83e\udde9 <strong data-start=\"4345\" data-end=\"4393\">Why Choose OOHMAGE Surge Protection Devices?<\/strong><\/h2>\n<p data-start=\"4447\" data-end=\"4525\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">OOHMAGE stands as a trusted surge protection manufacturer, combining quality, affordability, and performance. With advanced surge suppression technology and rigorous testing, we ensure that your investment in DC system safety delivers long-term peace of mind.<\/span><\/p>\n<h3 data-start=\"4527\" data-end=\"4544\">\ud83d\udcbc Ideal for:<\/h3>\n<ul data-start=\"4546\" data-end=\"4886\">\n<li data-start=\"4546\" data-end=\"4651\">\n<p data-start=\"4548\" data-end=\"4651\"><strong data-start=\"4548\" data-end=\"4568\">Solar Installers<\/strong> \u2013 <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Seeking reliable surge protection for PV systems.<\/span><\/p>\n<\/li>\n<li data-start=\"4653\" data-end=\"4767\">\n<p data-start=\"4655\" data-end=\"4767\"><strong data-start=\"4655\" data-end=\"4682\">Industrial Electricians<\/strong> \u2013 <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Requiring robust surge suppressors for DC circuits.<\/span><\/p>\n<\/li>\n<li data-start=\"4769\" data-end=\"4886\">\n<p data-start=\"4771\" data-end=\"4886\"><strong data-start=\"4771\" data-end=\"4801\">Energy Storage Integrators<\/strong> \u2013 <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Needing dependable surge protection for battery systems.<\/span><\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"5223\" data-end=\"5282\">\u2705 Certifications &amp; Compliance<\/h2>\n<ul data-start=\"5284\" data-end=\"5370\">\n<li data-start=\"5284\" data-end=\"5307\">\n<p data-start=\"5286\" data-end=\"5307\">T\u00dcV, CE, UKCA, CB<\/p>\n<\/li>\n<li data-start=\"5309\" data-end=\"5337\">\n<p data-start=\"5311\" data-end=\"5337\">RoHS &amp; REACH Compliant<\/p>\n<\/li>\n<li data-start=\"5339\" data-end=\"5370\">\n<p data-start=\"5341\" data-end=\"5370\">IEC\/EN 61643-11 Certified<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"5372\" data-end=\"5375\" \/>\n<h3 data-start=\"5377\" data-end=\"5417\">\ud83d\udcde Ready to Protect Your DC Systems?<\/h3>\n<p data-start=\"5419\" data-end=\"5501\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">Don\u2019t wait until a surge compromises your operations. Secure your DC systems with an OOHMAGE surge protector today. Bulk pricing and custom OEM\/ODM options available. Request a quote now!<\/span><\/p>\n<h2 data-start=\"4288\" data-end=\"4595\">Specifications<\/h2>\n<div class=\"table-1\">\n<div class=\"table-wrap\"><table class=\"hight-light-first-column all magic-10\">\n<tbody>\n<tr>\n<td colspan=\"6\" rowspan=\"1\">\n<div class=\"magic-11\"><b data-spm-anchor-id=\"a2700.custom-template.0.i24.1abb3333wzna3t\"><span class=\"magic-9\">Technical Data<\/span><\/b><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Model<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-18\">MDH6.25-DC600<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-14\">MDH6.25-DC800<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\">MDH6.25-DC1000<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-16\">MDH6.25-DC1200<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-19\">MDH6.25-DC1500<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">SPD Type<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">Type 1+2<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Technology<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">MOV (Metal Oxide Varistors)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Max. continuous operating voltage [Ucpv]<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-13\">600Vdc<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-14\">800Vdc<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\">1000Vdc<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-16\">1200Vdc<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-19\">1500Vdc<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Nominal discharge curent(8\/20us) [ln]<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-18\">20kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-14\"><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\"><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-16\"><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-19\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Max.discharge current (8\/20us) [lmax]<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-18\">40KA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-14\"><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\"><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-16\"><\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-19\"><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Impulse Discharge Current(10\/350us) [limp]<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-13\">6.25kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-19\">6.25kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\">6.25kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-16\">5kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-19\">3kA<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-21\">Impulse Discharge Current(10\/350us) [ltotal]<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-22\">12.5kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-19\">12.5kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\">12.5kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-23\">10kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-24\">6kA<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Voltage Protection level [Up]<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-13\">\u22642.6kV<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-14\">\u22643.2kV<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-15\">\u22643.8kV<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-16\">\u22644.5kV<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-19\">\u22645.2kV<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\" data-spm-anchor-id=\"a2700.details.0.i71.74d154b1J4kVpz\">Short-circuit current rating [Isccr]<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">25kA<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Response time [tA]<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">\u226425ns<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Thermal Disconnection Device<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">Insertion<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Max. Backup Fuse<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">63A gL\/gG FUSE<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\">\n<div class=\"magic-11\"><span class=\"magic-9\"><b>Mechanical Data<\/b><\/span><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">SPD Type<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">Type 1+2<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">SPD configuration<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">DC system<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Plugable<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">Available<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Mounting<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">35mm DIN rail<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Enclosure Material<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">Thermoplastic,conform to UL94 V-0<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">0perating Temperature Range<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">-40\u00b0C&#8230;-80\u00b0C<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Protection rating<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">IP20<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Normal\/fault Display<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">Green \/ Red<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Remote Signal<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">Optional<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Wiring for remote signaling<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">Max.1.5mm solid\/flexible<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Max.Voltage \/ Current for remote signaling<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">250V\/0.1A;125V\/0.2A;75V\/0.5A<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Standards<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">IEC\/EN 61643-11,GB\/T 18802.31<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Certificate<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">TUV,CE,UKCA,CB,IEC,RoHS,REACH,CQC<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" rowspan=\"1\">\n<div class=\"magic-11\"><b><span class=\"magic-9\">Packing Data<\/span><\/b><\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">3Pole<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">3+0\/3P<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Weight (1 piece)<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">400g<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">Package Quantity<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">48 PCS\/CTN<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"magic-17\">CTN Size<\/div>\n<\/td>\n<td colspan=\"5\" rowspan=\"1\">\n<div class=\"magic-20\">46*30.5*15.9cm<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n<h2>Certification<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" data-src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2025\/02\/875f8f6e58447fd7073c340938d49752-1.png\" class=\"size-full wp-image-5790 alignnone lazyload\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" alt=\"\"   \/><noscript><img decoding=\"async\" class=\"size-full wp-image-5790 alignnone\" src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2025\/02\/875f8f6e58447fd7073c340938d49752-1.png\" alt=\"\" width=\"1200\" height=\"700\"><\/noscript><\/p>\n<h3>What kind of environments is the surge protector suitable for?<\/h3>\n<div>\n<div>\n<div>\n<p>The surge protective devices are rated for IP20 protection, making them suitable for indoor use in environments with low exposure to dust and moisture. They can operate in temperatures from -40\u00b0C to +85\u00b0C, ensuring performance in diverse conditions.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<div>\n<div>\n<div>\n<h3>What is the response time of the surge protective device?<\/h3>\n<div>\n<div>\n<div>\n<p>The SPD offers an extremely fast response time of \u226425ns, ensuring your DC systems are protected from instantaneous surges and that the devices respond almost immediately to any surge event.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<div>\n<div>\n<div>\n<h3>What is the installation process for the surge protective device?<\/h3>\n<div>\n<div>\n<div>\n<p>The surge protectors are designed for easy installation on a 35mm DIN rail and feature screw terminal wiring for conductors between 2.5\u201325mm\u00b2, simplifying the connection process for both industrial and residential applications.<\/p>\n<h3>How do the surge protectors protect against lightning strikes?<\/h3>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<p>The SPD has a lightning impulse current rating of up to 12.5kA for 10\/350\u03bcs, which helps protect against lightning strikes and large surges, diverting harmful currents safely away from your electrical equipment.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<div>\n<div>\n<div>\n<h3>What is the maximum voltage the SPD can handle?<\/h3>\n<div>\n<div>\n<div>\n<p>The SPD can handle a maximum continuous operating voltage of 600Vdc to 1500Vdc, making it suitable for a wide range of solar power systems and other DC applications.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<div>\n<div>\n<div>\n<h3>What is a Type 1+2 surge protective device?<\/h3>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<div>\n<p>A Type 1+2 SPD provides both direct lightning strike protection (Type 1) and protection from residual and induced surges (Type 2). The OMYH9 series is designed to protect photovoltaic systems and DC electrical systems from both types of surges.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p data-start=\"875\" data-end=\"1021\">\u2714 <strong data-start=\"589\" data-end=\"626\">\u0e01\u0e32\u0e23\u0e1b\u0e49\u0e2d\u0e07\u0e01\u0e31\u0e19\u0e41\u0e1a\u0e1a\u0e04\u0e23\u0e1a\u0e27\u0e07\u0e08\u0e23\u0e2a\u0e33\u0e2b\u0e23\u0e31\u0e1a\u0e1b\u0e23\u0e30\u0e40\u0e20\u0e17 1+2<\/strong><br data-start=\"703\" data-end=\"706\" \/>\u2714 <strong data-start=\"708\" data-end=\"740\">\u0e04\u0e27\u0e32\u0e21\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e43\u0e19\u0e01\u0e32\u0e23\u0e23\u0e31\u0e1a\u0e21\u0e37\u0e2d\u0e01\u0e31\u0e1a\u0e01\u0e23\u0e30\u0e41\u0e2a\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e01\u0e23\u0e30\u0e0a\u0e32\u0e01\u0e2a\u0e39\u0e07<\/strong><br data-start=\"838\" data-end=\"841\" \/>\u2714 <strong data-start=\"843\" data-end=\"884\">\u0e40\u0e17\u0e04\u0e42\u0e19\u0e42\u0e25\u0e22\u0e35\u0e27\u0e32\u0e23\u0e34\u0e2a\u0e40\u0e15\u0e2d\u0e23\u0e4c\u0e2d\u0e2d\u0e01\u0e44\u0e0b\u0e14\u0e4c\u0e42\u0e25\u0e2b\u0e30 (MOV)<\/strong><br data-start=\"972\" data-end=\"975\" \/>\u2714 <strong data-start=\"977\" data-end=\"1008\">\u0e01\u0e32\u0e23\u0e2d\u0e2d\u0e01\u0e41\u0e1a\u0e1a\u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e25\u0e14\u0e41\u0e23\u0e07\u0e14\u0e31\u0e19\u0e40\u0e2b\u0e25\u0e37\u0e2d<\/strong><br data-start=\"1085\" data-end=\"1088\" \/>\u2714 <strong data-start=\"1090\" data-end=\"1126\">\u0e01\u0e32\u0e23\u0e15\u0e31\u0e14\u0e01\u0e32\u0e23\u0e40\u0e0a\u0e37\u0e48\u0e2d\u0e21\u0e15\u0e48\u0e2d\u0e17\u0e32\u0e07\u0e04\u0e27\u0e32\u0e21\u0e23\u0e49\u0e2d\u0e19\u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e04\u0e27\u0e32\u0e21\u0e1b\u0e25\u0e2d\u0e14\u0e20\u0e31\u0e22<\/strong><br data-start=\"1209\" data-end=\"1212\" \/>\u2714 <strong data-start=\"1214\" data-end=\"1242\">\u0e15\u0e31\u0e27\u0e40\u0e25\u0e37\u0e2d\u0e01\u0e01\u0e32\u0e23\u0e40\u0e1d\u0e49\u0e32\u0e15\u0e34\u0e14\u0e15\u0e32\u0e21\u0e08\u0e32\u0e01\u0e23\u0e30\u0e22\u0e30\u0e44\u0e01\u0e25<\/strong><br data-start=\"1335\" data-end=\"1338\" \/>\u2714 <strong data-start=\"1340\" data-end=\"1376\">\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u0e1b\u0e49\u0e2d\u0e07\u0e01\u0e31\u0e19\u0e44\u0e1f\u0e01\u0e23\u0e30\u0e0a\u0e32\u0e01\u0e41\u0e1a\u0e1a DIN Rail \u0e02\u0e19\u0e32\u0e14\u0e01\u0e30\u0e17\u0e31\u0e14\u0e23\u0e31\u0e14<\/strong><br data-start=\"1483\" data-end=\"1486\" \/>\u2714 <strong data-start=\"1488\" data-end=\"1512\">\u0e01\u0e32\u0e23\u0e23\u0e31\u0e1a\u0e23\u0e2d\u0e07\u0e04\u0e27\u0e32\u0e21\u0e2a\u0e2d\u0e14\u0e04\u0e25\u0e49\u0e2d\u0e07<\/strong><\/p>","protected":false},"featured_media":7240,"template":"","meta":{"_acf_changed":false,"rank_math_title":"High-Performance DC Surge Protector for Solar Systems \u2013 Type 1+2 SPD | OOHMAGE","rank_math_description":"Explore the OOHMAGE MDH6.25 Type 1+2 DC Surge Protector, engineered for superior surge protection in solar energy systems, industrial DC circuits, and battery storage applications.","rank_math_focus_keyword":"DC spd, DC Surge Protective Device, DIN Rail Surge Protector, Overvoltage Protection, Type 1+2 SPD, Lightning and Surge Protection, Photovoltaic Surge Protector","_product_sku":"","_product_attributes":[],"_product_faqs":[],"_product_image_gallery":""},"product_cat":[61,52],"product_tag":[],"class_list":["post-7144","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-outdoor-surge-protector","product_cat-dc-surge-protection-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.oohmage.com\/th\/wp-json\/wp\/v2\/product\/7144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oohmage.com\/th\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.oohmage.com\/th\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oohmage.com\/th\/wp-json\/wp\/v2\/media\/7240"}],"wp:attachment":[{"href":"https:\/\/www.oohmage.com\/th\/wp-json\/wp\/v2\/media?parent=7144"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.oohmage.com\/th\/wp-json\/wp\/v2\/product_cat?post=7144"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.oohmage.com\/th\/wp-json\/wp\/v2\/product_tag?post=7144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}