{"id":9870,"date":"2026-09-20T05:22:03","date_gmt":"2026-09-20T05:22:03","guid":{"rendered":"https:\/\/www.oohmage.com\/?p=9870"},"modified":"2026-09-21T01:11:49","modified_gmt":"2026-09-21T01:11:49","slug":"contactor-vs-circuit-breaker-vs-motor-starter","status":"publish","type":"post","link":"https:\/\/www.oohmage.com\/it\/contactor-vs-circuit-breaker-vs-motor-starter\/","title":{"rendered":"Contattore, interruttore automatico e avviatore motore"},"content":{"rendered":"<figure class=\"wp-block-image size-full is-resized\"><img data-srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce.png 832w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce-300x169.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce-18x10.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce-768x432.png 768w\" fetchpriority=\"high\" decoding=\"async\"   data-src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce.png\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" alt=\"\" class=\"wp-image-9871 lazyload\" style=\"aspect-ratio:1.7780748663101604;width:665px;height:auto\"  sizes=\"(max-width: 832px) 100vw, 832px\" \/><noscript><img decoding=\"async\" width=\"832\" height=\"468\" src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce.png\" alt=\"\" class=\"wp-image-9871\" style=\"aspect-ratio:1.7780748663101604;width:665px;height:auto\" srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce.png 832w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce-300x169.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce-18x10.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/e1254d34-5a49-4077-9fff-39ae3b7643ce-768x432.png 768w\" sizes=\"(max-width: 832px) 100vw, 832px\" \/><\/noscript><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em><strong>Figura 1. I contattori, gli interruttori automatici e i avviatori per motori svolgono diverse funzioni di controllo e protezione.<\/strong><\/em><\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questi tre dispositivi sono spesso presenti nello stesso quadro di comando del motore, ma risolvono problemi diversi. Un contattore gestisce le commutazioni frequenti, a distanza o automatiche durante il normale funzionamento. Un interruttore automatico interrompe le correnti anomale entro i limiti della sua capacit\u00e0 nominale. Un avviatore per motori combina solitamente un contattore con una protezione contro il sovraccarico del motore. In molti circuiti di comando dei motori, questi dispositivi operano in sinergia anzich\u00e9 in contrapposizione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questa guida mette a confronto tali funzioni, spiega in quali contesti trova applicazione un avviatore motore e indica le informazioni relative al progetto necessarie prima di scegliere un interruttore automatico industriale.<\/p>\n\n\n\n<h2 id=\"quick-answer-control-vs-protection\" class=\"wp-block-heading\">Risposta rapida: Controllo vs Protezione<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Partiamo dalla funzione. Un contattore commuta ripetutamente un carico in risposta a un segnale di controllo. Un interruttore automatico interrompe le correnti anomale in base al proprio schema di protezione. Un avviatore per motori combina la commutazione basata su contattori con la protezione da sovraccarico e necessita comunque di un adeguato sistema di protezione dai cortocircuiti. Un tipo di dispositivo non pu\u00f2 sostituire in modo sicuro un altro.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><div class=\"table-wrap\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Punto di riferimento<\/strong><\/td><td><strong>Contattore<\/strong><\/td><td><strong>Interruttore automatico<\/strong><\/td><td><strong>Avviatore motore<\/strong><\/td><\/tr><tr><td>Lavoro principale<\/td><td>Controllo di routine del carico<\/td><td>Protezione dei circuiti e delle apparecchiature<\/td><td>Avviamento del motore e protezione da sovraccarico<\/td><\/tr><tr><td>Funzionamento tipico<\/td><td>Comandi frequenti di avvio e arresto<\/td><td>Interruzioni durante i guasti; si apre per altre funzioni quando classificato<\/td><td>Avvia e arresta un motore tramite il relativo contattore<\/td><\/tr><tr><td>Come funziona<\/td><td>Segnale di controllo a bobina o elettronico<\/td><td>Meccanismo di sgancio, sgancio di sicurezza o azionamento manuale<\/td><td>Contattore pi\u00f9 rel\u00e8 di sovraccarico o protezione equivalente<\/td><\/tr><tr><td>Interruzione da cortocircuito<\/td><td>Non \u00e8 compito di un contattore di base<\/td><td>Una funzione primaria nell'ambito della capacit\u00e0 di interruzione nominale<\/td><td>Di norma dipende da un interruttore o da un fusibile coordinato<\/td><\/tr><tr><td>Valutazioni importanti<\/td><td>Categoria di carico, corrente, tensione della bobina, ciclo di lavoro<\/td><td>Tensione, corrente, poli, capacit\u00e0 di interruzione, caratteristiche di intervento<\/td><td>Dati del motore, potenza nominale del motorino di avviamento, servizio del contattore, intervallo di sovraccarico<\/td><\/tr><\/tbody><\/table><\/div><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img data-srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-1024x576.png 1024w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-300x169.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-768x432.png 768w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-18x10.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-1536x864.png 1536w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles.png 1600w\" decoding=\"async\"   data-src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-1024x576.png\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" alt=\"\" class=\"wp-image-9872 lazyload\" style=\"aspect-ratio:1.778735632183908;width:619px;height:auto\"  sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-1024x576.png\" alt=\"\" class=\"wp-image-9872\" style=\"aspect-ratio:1.778735632183908;width:619px;height:auto\" srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-1024x576.png 1024w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-300x169.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-768x432.png 768w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-18x10.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles-1536x864.png 1536w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/02-roles.png 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em><strong>Figura 2. Inizio con la funzione: i contattori controllano, gli interruttori automatici proteggono e gli avviatori per motori combinano la commutazione con la protezione dal sovraccarico del motore.<\/strong><\/em><\/strong><strong><\/strong><\/p>\n\n\n\n<h2 id=\"what-a-contactor-does\" class=\"wp-block-heading\">Cosa fa un contattore<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un contattore \u00e8 un interruttore a comando elettrico. Quando la bobina riceve la tensione di comando corretta, il suo meccanismo magnetico modifica lo stato dei contatti principali e consente all'energia elettrica di raggiungere il carico. L'interruzione del segnale di comando riporta i contatti al loro stato normale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ci\u00f2 separa il circuito di comando dal circuito di carico. Pulsanti, temporizzatori, rel\u00e8, controllori logici programmabili e sistemi di controllo degli edifici possono comandare un carico molto pi\u00f9 grande senza dover sostenere essi stessi la corrente di carico. Lo stesso principio rende i contattori utili negli avviatori per motori, nelle pompe, nei ventilatori, nei compressori, nei nastri trasportatori, nei gruppi di illuminazione e nelle apparecchiature HVAC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La corrente \u00e8 solo uno dei fattori da considerare nella scelta di un contattore. Il progettista deve inoltre verificare il tipo di carico, la tensione di esercizio, la categoria di utilizzo, la frequenza di commutazione prevista, la tensione della bobina, la corrente di avviamento, le condizioni ambientali e la durata elettrica richiesta. Un dispositivo adatto a un carico resistivo potrebbe non essere adatto all\u2019avviamento ripetuto di un motore alla stessa corrente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un contattore di base non sostituisce la protezione da cortocircuito. Alcuni prodotti vengono commercializzati come avviatori coordinati o gruppi che includono un rel\u00e8 di sovraccarico o una protezione elettronica, ma tali funzioni aggiuntive sono proprie del gruppo o del dispositivo aggiunto. Non devono essere dedotte dalla sola parola \u201ccontattore\u201d. Per una spiegazione pi\u00f9 completa del meccanismo di commutazione, si veda <a href=\"https:\/\/www.oohmage.com\/it\/what-is-a-contactor-and-how-does-it-work\/\">cos\u2019\u00e8 un contattore e come funziona<\/a>.<\/p>\n\n\n\n<h2 id=\"what-a-circuit-breaker-does\" class=\"wp-block-heading\">Come funziona un interruttore automatico<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un interruttore automatico \u00e8 un dispositivo di commutazione di protezione. Il suo tipo e l'unit\u00e0 di intervento determinano se rileva o reagisce a correnti di sovraccarico, correnti di cortocircuito o altre condizioni anomale definite prima di interrompere il circuito entro i valori nominali specificati.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La scelta dell'interruttore deve partire dal sistema, non dal valore in ampere riportato sull'etichetta. Il progettista deve verificare la tensione, il tipo di applicazione (corrente alternata o continua), la corrente nominale, il numero di poli, la corrente di guasto disponibile, la capacit\u00e0 di interruzione richiesta, le caratteristiche di intervento, il coordinamento con i dispositivi a monte e a valle e le condizioni di installazione. Non approvare un interruttore basandosi esclusivamente sulla corrente nominale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gli interruttori automatici in involucro stampato sono utilizzati nella distribuzione industriale, nella protezione delle linee di alimentazione, nella realizzazione di quadri elettrici e in alcune applicazioni relative ai circuiti dei motori. I modelli termomagnetici combinano solitamente la protezione da sovraccarico e da cortocircuito. Le unit\u00e0 di scatto elettroniche possono aggiungere funzioni di protezione regolabili. In entrambi i casi, le caratteristiche precise dipendono dalla serie e dal modello selezionati, non dalla categoria di prodotto nel suo complesso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sebbene un interruttore possa essere azionato manualmente, la sua funzione di protezione non lo rende automaticamente un sostituto del contattore. Le commutazioni operative frequenti possono comportare un carico di lavoro diverso rispetto all\u2019azionamento manuale occasionale o all\u2019interruzione in caso di guasto. Utilizzare un interruttore per le commutazioni di routine solo quando il produttore lo certifica esplicitamente per tale applicazione. \u00c8 possibile consultare il meccanismo di protezione di base in <a href=\"https:\/\/www.oohmage.com\/it\/how-does-a-circuit-breaker-work\/\">Come funziona un interruttore automatico<\/a>.<\/p>\n\n\n\n<h2 id=\"what-a-motor-starter-includes\" class=\"wp-block-heading\">Cosa comprende un avviatore motore<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un avviatore per motori \u00e8 un gruppo completo, non un altro nome per indicare un contattore. Un comune avviatore magnetico combina un contattore per la commutazione del motore con un rel\u00e8 di sovraccarico che interviene in caso di condizioni di sovraccarico prolungato entro i propri limiti nominali. Il gruppo pu\u00f2 inoltre includere un involucro, pulsanti di comando, contatti ausiliari o altri accessori.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Questa \u00e8 la differenza pratica che sta alla base delle ricerche relative a \u201cavviatore motore vs contattore\u201d e \u201ccontattore vs avviatore\u201d. Il contattore \u00e8 un componente fondamentale all\u2019interno dell\u2019avviatore. L\u2019avviatore aggiunge protezione da sovraccarico e funzioni di controllo ausiliarie, ma non garantisce automaticamente un\u2019adeguata interruzione in caso di cortocircuito. A meno che un gruppo di protezione specifico non fornisca e verifichi esplicitamente tale funzione, il circuito necessita comunque di un interruttore o di un fusibile coordinato.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Il termine \u201cmotorino di avviamento\u201d si riferisce spesso a un componente automobilistico, pertanto non va confuso con un avviatore per motori industriali. In questo articolo, per \u201cavviatore per motori\u201d si intende un\u2019apparecchiatura elettrica utilizzata per avviare, arrestare e proteggere un motore industriale o commerciale.<\/p>\n\n\n\n<h2 id=\"contactor-vs-circuit-breaker-comparison\" class=\"wp-block-heading\">Confronto tra contattore e interruttore automatico<strong><\/strong><\/h2>\n\n\n\n<h2 id=\"different-jobs-in-the-same-circuit\" class=\"wp-block-heading\">Lavori diversi nello stesso circuito<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un contattore risponde: \u2018Quando deve funzionare il carico?\u2019. Un interruttore automatico risponde: \u2018Cosa deve interrompere il circuito quando la corrente supera il limite consentito?\u2019.\u2019<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Entrambi i dispositivi sono dotati di contatti ed entrambi sono in grado di interrompere la corrente, il che fa sembrare il confronto pi\u00f9 semplice di quanto non sia in realt\u00e0. I loro contatti, i meccanismi di azionamento e i sistemi di controllo dell\u2019arco sono progettati per funzioni diverse. Un contattore \u00e8 ottimizzato per la commutazione comandata; un interruttore \u00e8 progettato e dimensionato per eliminare specifiche condizioni di guasto.<\/p>\n\n\n\n<h2 id=\"switching-frequency-and-operating-life\" class=\"wp-block-heading\">Frequenza di commutazione e durata di funzionamento<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le apparecchiature industriali possono avviarsi e arrestarsi numerose volte nel corso di un turno di lavoro. Un contattore scelto correttamente \u00e8 progettato per sopportare tale carico operativo ripetitivo, e la sua bobina garantisce un collegamento pratico a dispositivi di interblocco, circuiti logici di controllo di emergenza, temporizzatori, sensori e sistemi di automazione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un interruttore automatico viene normalmente azionato con frequenza molto minore. Conduce corrente in modo continuo, interviene in caso di guasti e pu\u00f2 fungere da punto di interruzione quando il dispositivo selezionato \u00e8 idoneo all\u2019isolamento. I valori nominali del prodotto determinano il numero e il tipo di operazioni consentite. Non esiste un numero universale di operazioni: verificare i dati del produttore relativi al modello e alle condizioni di esercizio specifici.<\/p>\n\n\n\n<h2 id=\"fault-interruption-and-breaking-capacity\" class=\"wp-block-heading\">Interruzione in caso di guasto e capacit\u00e0 di interruzione<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La capacit\u00e0 di interruzione pu\u00f2 escludere un interruttore anche quando la sua corrente nominale di funzionamento sembra corretta. Il dispositivo deve interrompere la corrente di guasto prevista nel punto di installazione, nei limiti dei valori nominali e delle condizioni applicabili. Se la corrente di guasto disponibile supera tale capacit\u00e0, il fatto che la corrente di funzionamento sia adeguata non render\u00e0 l'installazione sicura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La capacit\u00e0 di commutazione a carico normale di un contattore non corrisponde alla sua capacit\u00e0 di\u77ed\u8def. In presenza di una corrente di guasto elevata, il contattore potrebbe non riuscire a interrompere il circuito in modo sicuro, i suoi contatti potrebbero saldarsi oppure potrebbe subire gravi danni. Ecco perch\u00e9 il circuito necessita di una protezione contro i cortocircuiti a monte.<\/p>\n\n\n\n<h2 id=\"control-signals-and-automation\" class=\"wp-block-heading\">Segnali di controllo e automazione<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La bobina del contattore collega il sistema di controllo al circuito di potenza. Un segnale di controllo relativamente debole \u00e8 in grado di azionare un motore o un altro carico, mentre i contatti ausiliari segnalano lo stato o garantiscono l'interblocco.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alcuni interruttori automatici sono inoltre compatibili con accessori quali dispositivi di scatto in derivazione, rel\u00e8 di sottotensione, azionamenti motorizzati e contatti ausiliari. Queste opzioni consentono lo scatto, la segnalazione o l\u2019azionamento a distanza, ma non rendono ogni interruttore adatto a commutazioni ad alto numero di cicli. Verificare la compatibilit\u00e0 degli accessori e le condizioni di esercizio per il modello specifico.<\/p>\n\n\n\n<h2 id=\"overload-protection-is-a-separate-design-question\" class=\"wp-block-heading\">La protezione da sovraccarico \u00e8 una questione progettuale a s\u00e9 stante<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La protezione da cortocircuito e quella da sovraccarico del motore riguardano eventi diversi. Un cortocircuito pu\u00f2 generare una corrente molto elevata che deve essere interrotta rapidamente. Un sovraccarico del motore pu\u00f2 avere un\u2019intensit\u00e0 inferiore, ma persistere abbastanza a lungo da causare il surriscaldamento del motore. Considerare entrambi come un unico criterio di selezione comporta una lacuna nella protezione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Alcuni interruttori di protezione dei motori combinano la protezione da cortocircuito con una protezione da sovraccarico regolabile. Un\u2019altra configurazione comune prevede l\u2019uso di un interruttore o di un fusibile per la protezione da cortocircuito, un contattore per la commutazione e un rel\u00e8 di sovraccarico per la protezione del motore dal sovraccarico. La scelta tra queste opzioni deve basarsi sul motore, sul metodo di avviamento, sull\u2019alimentazione, sui requisiti di controllo, sui dati di coordinamento e sulle norme locali.<\/p>\n\n\n\n<h2 id=\"why-motor-circuits-often-need-both\" class=\"wp-block-heading\">Perch\u00e9 i circuiti dei motori spesso necessitano di entrambi<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un percorso comune di controllo del motore assegna le funzioni nel seguente ordine:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Alimentazione \u2192 Interruttore automatico o fusibile \u2192 Contattore \u2192 Protezione da sovraccarico, se necessaria \u2192 Motore<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ogni elemento ha una funzione specifica:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Il dispositivo di protezione a monte interrompe la corrente di cortocircuito e garantisce le funzioni di protezione da sovracorrente previste dal progetto.<\/li>\n\n\n\n<li>Il contattore avvia e arresta il motore in risposta ai comandi di controllo.<\/li>\n\n\n\n<li>Un rel\u00e8 di sovraccarico o una funzione dedicata alla protezione del motore interviene in caso di sovraccarico prolungato, blocco del rotore, perdita di fase o altre condizioni che rientrano nei limiti di funzionamento specificati.<\/li>\n\n\n\n<li>\u00c8 necessario verificare la combinazione completa in termini di coordinamento, corrente di guasto disponibile, caratteristiche del carico e requisiti regionali applicabili.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img data-srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-1024x512.png 1024w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-300x150.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-768x384.png 768w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-18x9.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-1536x768.png 1536w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path.png 1600w\" loading=\"lazy\" decoding=\"async\"   data-src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-1024x512.png\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" alt=\"\" class=\"wp-image-9873 lazyload\" style=\"aspect-ratio:2.0032362459546924;width:619px;height:auto\"  sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-1024x512.png\" alt=\"\" class=\"wp-image-9873\" style=\"aspect-ratio:2.0032362459546924;width:619px;height:auto\" srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-1024x512.png 1024w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-300x150.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-768x384.png 768w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-18x9.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path-1536x768.png 1536w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/03-motor-control-path.png 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em><strong>Figura 3. Un tipico percorso di controllo del motore assegna la protezione da cortocircuito, la commutazione e la protezione da sovraccarico a funzioni separate e coordinate tra loro.<\/strong><\/em><\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le linee guida di Schneider Electric sulla protezione dei motori descrivono gli interruttori magnetotermici per motori che garantiscono protezione da cortocircuito e sovraccarico, e illustrano inoltre sistemi che abbinano un interruttore magnetico o un fusibile a un rel\u00e8 di sovraccarico separato. Anche le linee guida applicative di ABB trattano i motori controllati da contattori e quelli controllati da interruttori automatici come schemi di protezione distinti. La scelta di un componente non elimina la necessit\u00e0 di assegnare tutte le funzioni di controllo e protezione richieste.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per informazioni sull'architettura del prodotto correlato, consultare il <a href=\"https:\/\/www.oohmage.com\/it\/motor-protection-circuit-breaker\/\">interruttore di protezione del motore<\/a>&nbsp;categoria. La progettazione definitiva e la verifica devono essere eseguite da personale qualificato. Il presente articolo non fornisce istruzioni relative alle prove sotto tensione, ai bypass o al cablaggio in campo.<\/p>\n\n\n\n<h2 id=\"which-device-do-you-need\" class=\"wp-block-heading\">Di quale dispositivo hai bisogno?<strong><\/strong><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><div class=\"table-wrap\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Compito dell'acquirente<\/strong><\/td><td><strong>Probabile disposizione funzionale<\/strong><\/td><td><strong>Ci\u00f2 che deve ancora essere confermato<\/strong><\/td><\/tr><tr><td>Avviare e arrestare un motore da remoto e con frequenza<\/td><td>Contattore pi\u00f9 protezione adeguata<\/td><td>Dati del motore, modalit\u00e0 di avviamento, rapporto di accensione, coordinamento<\/td><\/tr><tr><td>Proteggere un alimentatore industriale<\/td><td>Interruttore automatico adeguato<\/td><td>Tensione, corrente di carico, corrente di guasto, poli, requisiti di intervento<\/td><\/tr><tr><td>Automatizzare un carico e proteggere il circuito<\/td><td>Contattore e interruttore automatico, con protezione da sovraccarico se richiesta<\/td><td>Tensione di comando, categoria di carico, funzioni di protezione, coordinamento<\/td><\/tr><tr><td>Garantire l'isolamento per la manutenzione<\/td><td>Un dispositivo espressamente adatto all'isolamento<\/td><td>Segnalazione di isolamento, metodo di blocco, requisiti locali<\/td><\/tr><\/tbody><\/table><\/div><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img data-srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-1024x576.png 1024w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-300x169.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-768x432.png 768w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-18x10.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-1536x864.png 1536w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide.png 1600w\" loading=\"lazy\" decoding=\"async\"   data-src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-1024x576.png\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" alt=\"\" class=\"wp-image-9874 lazyload\" style=\"aspect-ratio:1.778735632183908;width:619px;height:auto\"  sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-1024x576.png\" alt=\"\" class=\"wp-image-9874\" style=\"aspect-ratio:1.778735632183908;width:619px;height:auto\" srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-1024x576.png 1024w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-300x169.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-768x432.png 768w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-18x10.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide-1536x864.png 1536w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/04-selection-guide.png 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em><strong>Figura 4. Selezionare la categoria del dispositivo in base all'incarico, quindi verificare il modello esatto confrontandolo con i dati relativi al sistema, al carico, ai guasti e al coordinamento.<\/strong><\/em><\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Utilizza la tabella per identificare il tipo di dispositivo da inserire nel circuito. Non utilizzarla per scegliere un modello specifico. Tale decisione richiede comunque i dati del progetto e le informazioni di coordinamento fornite dal produttore.<\/p>\n\n\n\n<h2 id=\"how-to-specify-the-circuit-breaker-side\" class=\"wp-block-heading\">Come specificare il lato dell'interruttore automatico<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Prima di richiedere una proposta o un preventivo per un interruttore magnetotermico (MCCB), preparate i seguenti dati:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Sistema in corrente alternata o continua e tensione nominale.<\/li>\n\n\n\n<li>Tipo di carico, corrente di esercizio e condizioni di avviamento previste.<\/li>\n\n\n\n<li>Numero richiesto di pali e informazioni relative al sistema di messa a terra.<\/li>\n\n\n\n<li>Corrente di guasto disponibile nel punto di installazione o capacit\u00e0 di interruzione richiesta.<\/li>\n\n\n\n<li>Caratteristiche richieste di protezione contro i sovraccarichi e i cortocircuiti.<\/li>\n\n\n\n<li>Requisiti di coordinamento a monte e a valle o di selettivit\u00e0.<\/li>\n\n\n\n<li>Ambiente di installazione, condizioni dell'involucro e frequenza di funzionamento.<\/li>\n\n\n\n<li>Quantit\u00e0, mercato di destinazione e documentazione tecnica richiesta.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img data-srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-1024x576.png 1024w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-300x169.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-768x432.png 768w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-18x10.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-1536x864.png 1536w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist.png 1600w\" loading=\"lazy\" decoding=\"async\"   data-src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-1024x576.png\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" alt=\"\" class=\"wp-image-9875 lazyload\" style=\"aspect-ratio:1.778735632183908;width:619px;height:auto\"  sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><noscript><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-1024x576.png\" alt=\"\" class=\"wp-image-9875\" style=\"aspect-ratio:1.778735632183908;width:619px;height:auto\" srcset=\"https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-1024x576.png 1024w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-300x169.png 300w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-768x432.png 768w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-18x10.png 18w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist-1536x864.png 1536w, https:\/\/www.oohmage.com\/wp-content\/uploads\/2026\/09\/05-mccb-quote-checklist.png 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/noscript><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em><strong>Figura 5. Per ottenere un preventivo relativo a un interruttore MCCB sono necessari dati completi relativi all\u2019impianto, al carico, ai guasti, alle protezioni e al progetto, non solo il valore nominale della corrente.<\/strong><\/em><\/strong><strong><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Non richiedere un interruttore magnetotermico (MCCB) basandosi esclusivamente sul valore nominale in ampere. La serie completa di dati di input consente al fornitore di confrontare le opzioni termomagnetiche, elettroniche, regolabili e per corrente continua senza estendere le caratteristiche di un singolo modello all\u2019intera famiglia di prodotti. Se mancano ancora dati fondamentali relativi al progetto, la raccomandazione sul modello non \u00e8 ancora pronta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">OOHMAGE offre diverse serie di interruttori automatici MCCB per la distribuzione industriale e la scelta in base alle esigenze progettuali. Consulta la <a href=\"https:\/\/www.oohmage.com\/it\/molded-case-circuit-breaker\/\">Serie di interruttori automatici in involucro stampato<\/a>&nbsp;e verificare che i parametri pubblicati del modello specifico corrispondano a quelli del progetto prima di effettuare l'ordine. Non dare per scontato che una serie sia adatta solo perch\u00e9 la sua gamma attuale sembra simile.<\/p>\n\n\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">Errori comuni<strong><\/strong><\/h2>\n\n\n\n<h3 id=\"using-a-contactor-as-short-circuit-protection\" class=\"wp-block-heading\">Utilizzo di un contattore come protezione da cortocircuito<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un contattore pu\u00f2 aprire un carico durante il normale funzionamento, ma ci\u00f2 non gli conferisce alcuna capacit\u00e0 di interruzione in caso di guasto propria di un interruttore automatico. Il circuito necessita comunque di un dispositivo di protezione adeguato.<\/p>\n\n\n\n<h3 id=\"using-a-breaker-for-frequent-automatic-switching\" class=\"wp-block-heading\">Utilizzo di un interruttore per commutazioni automatiche frequenti<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L'utilizzo di un interruttore come un contattore pu\u00f2 comportare un sovraccarico rispetto al ciclo di funzionamento previsto per quel dispositivo. Verificare i valori nominali di commutazione specifici oppure utilizzare un contattore progettato per il ciclo di funzionamento richiesto.<\/p>\n\n\n\n<h3 id=\"confusing-overload-and-short-circuit-protection\" class=\"wp-block-heading\">Confusione tra protezione da sovraccarico e protezione da cortocircuito<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sia le condizioni di sovraccarico che quelle di cortocircuito comportano una corrente eccessiva, ma la loro entit\u00e0, durata e la risposta richiesta differiscono. Un motore potrebbe necessitare di una protezione da sovraccarico oltre alla protezione da cortocircuito a monte.<\/p>\n\n\n\n<h3 id=\"selecting-only-by-rated-current\" class=\"wp-block-heading\">Selezione solo in base alla corrente nominale<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La corrente nominale \u00e8 il punto di partenza. La tensione, l\u2019idoneit\u00e0 al funzionamento in corrente alternata o continua, la categoria di carico, la corrente di guasto disponibile, la capacit\u00e0 di interruzione, il numero di poli, il comportamento di intervento e le condizioni ambientali sono tutti fattori che possono influenzare la scelta.<\/p>\n\n\n\n<h3 id=\"assuming-ac-and-dc-ratings-are-interchangeable\" class=\"wp-block-heading\">Ipotesi di intercambiabilit\u00e0 dei valori nominali CA e CC<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L'interruzione in corrente continua comporta requisiti diversi in termini di controllo dell'arco. Utilizzare un modello con valori nominali pubblicati per la tensione in corrente continua effettiva e la configurazione dei poli. Non applicare i valori nominali previsti per la corrente alternata sulla base di supposizioni.<\/p>\n\n\n\n<h3 id=\"ignoring-coordination\" class=\"wp-block-heading\">Ignorare il coordinamento<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un interruttore, un contattore e un rel\u00e8 di sovraccarico devono funzionare come un unico sistema. Verificare i dati di coordinamento forniti dal produttore e i requisiti locali; la corrispondenza delle etichette relative alla corrente non garantisce che la combinazione sia adeguata.<\/p>\n\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Domande frequenti<strong><\/strong><\/h2>\n\n\n\n<h3 id=\"can-a-contactor-replace-a-circuit-breaker\" class=\"wp-block-heading\">Un contattore pu\u00f2 sostituire un interruttore automatico?<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. Un contattore di base controlla un carico durante il normale funzionamento; non sostituisce un interruttore automatico o un fusibile progettato per interrompere la corrente di cortocircuito. Qualsiasi circuito che utilizzi un contattore necessita comunque di un\u2019adeguata protezione a monte.<\/p>\n\n\n\n<h3 id=\"can-a-circuit-breaker-replace-a-contactor\" class=\"wp-block-heading\">Un interruttore automatico pu\u00f2 sostituire un contattore?<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Di solito no, quando il carico richiede commutazioni frequenti, remote o automatiche. Un interruttore pu\u00f2 supportare il funzionamento manuale, accessori di comando remoto o funzioni di commutazione specifiche, ma il dispositivo e l\u2019applicazione devono essere specificatamente omologati per tale uso.<\/p>\n\n\n\n<h3 id=\"why-is-an-overload-relay-used-with-a-contactor\" class=\"wp-block-heading\">Perch\u00e9 si utilizza un rel\u00e8 di sovraccarico con un contattore?<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il contattore aziona il motore. Il rel\u00e8 di sovraccarico monitora le condizioni di corrente prolungata che potrebbero causarne il surriscaldamento e interrompe il circuito di comando quando necessario. La protezione da cortocircuito rimane di competenza di un interruttore o di un fusibile adeguato, a meno che un dispositivo coordinato non svolga entrambe le funzioni.<\/p>\n\n\n\n<h3 id=\"do-all-motor-circuits-need-both-devices\" class=\"wp-block-heading\">Tutti i circuiti elettrici richiedono entrambi i dispositivi?<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Non esiste una configurazione unica adatta a tutti i circuiti motore. I dispositivi necessari dipendono dalla potenza del motore, dal metodo di avviamento, dall\u2019alimentazione, dalle esigenze di controllo, dallo schema di protezione, dai dati di coordinamento e dalle normative locali. Molti circuiti motore automatizzati utilizzano sia un contattore che un dispositivo di protezione, poich\u00e9 la commutazione e la protezione dai guasti rimangono funzioni distinte.<\/p>\n\n\n\n<h3 id=\"what-information-is-needed-for-an-mccb-quotation\" class=\"wp-block-heading\">Quali informazioni sono necessarie per un preventivo relativo a un interruttore MCCB<strong><\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Indicare la tensione di sistema, il tipo di alimentazione (CA o CC), la corrente nominale, il numero di poli, la capacit\u00e0 di interruzione richiesta, il metodo di protezione, il carico o l'applicazione, la quantit\u00e0, le condizioni di installazione e il mercato di destinazione. Selezionare il modello solo dopo aver verificato i dati pubblicati relativi alla serie di interruttori MCCB proposta.<\/p>\n\n\n\n<h2 id=\"final-takeaway\" class=\"wp-block-heading\">Conclusione finale<strong><\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un contattore controlla il funzionamento normale. Un interruttore automatico protegge da condizioni di corrente anomale predefinite. Il fatto che abbiano un aspetto simile all\u2019interno di un quadro elettrico non rende i loro valori nominali o le loro funzioni intercambiabili. Molti circuiti dei motori utilizzano quindi un interruttore automatico o un fusibile per la protezione dai guasti, un contattore per il controllo di avvio e arresto e, ove necessario, un rel\u00e8 di sovraccarico o una funzione dedicata alla protezione del motore.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Assegnare prima ciascuna funzione, quindi selezionare i dispositivi in base ai parametri di progetto verificati. Per il lato degli interruttori di un quadro industriale, inviare i dati relativi a tensione, corrente, poli, capacit\u00e0 di interruzione richiesta, applicazione, quantit\u00e0 e mercato di destinazione tramite il <a href=\"https:\/\/www.oohmage.com\/it\/contact\/\">Pagina dei contatti di OOHMAGE<\/a>. Se una serie OOHMAGE \u00e8 compatibile, la risposta dovrebbe spiegare il motivo e indicare la documentazione tecnica disponibile. Se nessuna serie \u00e8 compatibile, non forzare la scelta.<\/p>\n\n\n\n<h2 id=\"technical-references\" class=\"wp-block-heading\">Riferimenti tecnici<strong><\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.se.com\/ca\/en\/product-subcategory\/38342932-motor-protection-circuit-breakers\/\" rel=\"noopener\">Interruttori automatici Schneider Electric per la protezione dei motori<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.electrical-installation.org\/enwiki\/Basic_motor_protection_scheme%3A_circuit-breaker_%2B_contactor_%2B_thermal_relay\" rel=\"noopener\">Schema di protezione di base dei motori di Schneider Electric<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/new.abb.com\/medium-voltage\/digital-substations\/protection-relays\/motor-protection-and-control\" rel=\"noopener\">Protezione e controllo dei motori ABB<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/library.e.abb.com\/public\/0b4f0e5be0152a69c12572c2002fb9ae\/1SDC210015D0202.pdf\" rel=\"noopener\">Guida all'uso degli interruttori automatici ABB per la protezione dei motori<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Figure 1. Contactors, circuit breakers, and motor starters solve different control and protection tasks. These three devices often appear in the same motor-control panel, but they solve different problems. A contactor handles frequent, remote, or automatic switching during normal operation. A circuit breaker interrupts abnormal current within its rated capability. A motor starter normally combines [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":9876,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":"","rank_math_title":"","rank_math_description":"","rank_math_focus_keyword":""},"categories":[92,91],"tags":[],"class_list":["post-9870","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-circuit-breakers","category-electrical-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/posts\/9870","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/comments?post=9870"}],"version-history":[{"count":2,"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/posts\/9870\/revisions"}],"predecessor-version":[{"id":9878,"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/posts\/9870\/revisions\/9878"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/media\/9876"}],"wp:attachment":[{"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/media?parent=9870"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/categories?post=9870"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.oohmage.com\/it\/wp-json\/wp\/v2\/tags?post=9870"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}