OMDN40-AC Type 2 AC Surge Protective Device
OMDN40-AC is a Type 2 AC surge protective device series. Compare the Uc voltage versions and the applicable discharge ratings before specifying a device for the project.
Electrical Specifications by Voltage Version
| Parameter | 275 V AC | 320 V Wechselstrom | 385 V Wechselstrom | 440 V AC |
|---|---|---|---|---|
| SPD type | Typ 2 | Typ 2 | Typ 2 | Typ 2 |
| AC operating voltage Un | 230 V Wechselstrom | 230 V Wechselstrom | 230 V Wechselstrom | 230 V Wechselstrom |
| Maximale Dauerbetriebsspannung Uc | 275 V AC | 320 V Wechselstrom | 385 V Wechselstrom | 440 V AC |
| Nominal discharge current In (8/20 µs) | 20 kA | 20 kA | 20 kA | 20 kA |
| Maximum discharge current Imax (8/20 µs) | 40 kA | 40 kA | 40 kA | 40 kA |
| Voltage protection level Up | ≤1,5 kV | ≤1,6 kV | ≤ 1,8 kV | ≤ 2,0 kV |
| Short-circuit current rating Isccr | 25 kA | 25 kA | 25 kA | 25 kA |
| Maximum backup fuse | 63A gG fuse | 63A gG fuse | 63A gG fuse | 63A gG fuse |
Use the column for the selected voltage version. Confirm the supply system, protection configuration and upstream coordination before ordering.
Installation and Mechanical Data
| Main terminal conductors | Screw terminal, 2.5–25mm² |
|---|---|
| Normal / fault indication | Green / red |
| Remote contact maximum load | 250V / 0.5A AC; 30V / 3A DC |
| Remote signal conductor cross-section | Maximum 1.5mm² |
| Installation | 35-mm-DIN-Schiene |
| Betriebstemperatur | -40°C to +85°C |
| Schutzstufe | IP20 |
| Gehäusematerial | Thermoplastic material, UL94 V-0 |
| Applicable standard reference | IEC/EN 61643-11; GB/T 18802.11 |
The device is rated IP20. IP20 does not provide weatherproof protection. For outdoor panels or exposed locations, confirm a suitable protective enclosure and the installation conditions. Coordinate the backup fuse with the selected device and circuit.
Documents and Order Confirmation
Request the applicable datasheet, dimensional drawing, installation instructions and available certification documents for the exact OOHMAGE model. Confirm the document holder, model coverage, destination market, supply scope and packaging with the quotation.
Vor Ihrer Angebotsanfrage
Send the AC system voltage, earthing arrangement, required SPD type, pole configuration, discharge ratings, quantity and installation environment.
Compare the OOHMAGE SPD range or use the quotation form below.
Angebot anfordern
Teilen Sie uns Ihre Anforderungen, die Menge oder den Anwendungsfall mit, und wir unterbreiten Ihnen ein maßgeschneidertes Angebot.